radarx.retrieve.coldpool.buoyancy#

radarx.retrieve.coldpool.buoyancy(theta_v, reference, *, condensate=None)[source]#

Buoyancy from the virtual potential temperature.

\(B = g (\theta_v - \overline{\theta_v}) / \overline{\theta_v} - g r_c\), the standard form with hydrometeor loading (e.g. Markowski and Richardson [1]; equation number not checked against the book). \(g\) = 9.80665 m s-2 is the standard gravity, a radarx choice of constant.

Parameters:
  • theta_v (xarray.DataArray) – Virtual potential temperature (K).

  • reference (xarray.DataArray or float) – Reference (environmental) virtual potential temperature, broadcast against theta_v.

  • condensate (xarray.DataArray or float, optional) – Condensate mixing ratio (kg kg-1) for the hydrometeor loading. Without it the buoyancy of precipitating air is overestimated (the cold-pool intensity underestimated).

Returns:

xarray.DataArray – buoyancy (m s-2) on the coordinates of theta_v.