radarx.fundamentals.power.compute_average_power#

radarx.fundamentals.power.compute_average_power(peak_power, duty_cycle)[source]#

Compute average power from peak power and duty cycle.

P_ave = P_t * f with duty cycle f = tau * PRF, Rinehart [1] (Chapter 13, p. 193, “Quantification”).

Parameters:
  • peak_power (float) – Peak transmitted power [W].

  • duty_cycle (float) – Duty cycle (0 < value < 1).

Returns:

float – Average power [W].

References