radarx.fundamentals.doppler.dual_prf_velocity#

radarx.fundamentals.doppler.dual_prf_velocity(wavelength, prf1, prf2)[source]#

Compute Nyquist velocity using dual-PRF scheme.

Parameters:
  • wavelength (float) – Radar wavelength [m]

  • prf1 (float) – First PRF [Hz]

  • prf2 (float) – Second PRF [Hz]

Returns:

float – Maximum unambiguous velocity from dual-PRF scheme [m/s]

Notes

The sign of the result depends on the order of PRF values. Ensure prf1 > prf2 for positive velocity.